Daikin Thermostat Error Codes



The reason for the incomplete operation of the thermostat can be a breakdown of the device itself, as the problems with the voltage in the power supply and not only. Below are the tables containing information about Daikin thermostats. In each table you will find information about different models of this brand: fault codes, its causes and repair methods.

Daikin CTXU25G2V1B Thermostat Error Codes

ErrorCause
A1Indoor unit PCB abnormality
PCBFreeze-up protection or high pressure control
A5Fan motor or related abnormality
A6Indoor heat exchanger thermistor abnormality
C4Room temperature thermistor abnormality
C9Humidity sensor abnormality
CCOutdoor unit PCB abnormality
E1OL activation (compressor overload)
E5Compressor lock
E6DC fan lock
E7Input overcurrent detection
E8Discharge pipe temperature control
F3High pressure control in cooling
F6Compressor sensor system abnormality
H0Damper abnormality
H1Position sensor abnormality
H6DC voltage / DC current sensor abnormality
H8Outdoor air thermistor abnormality
H9Discharge pipe thermistor abnormality
J3Outdoor heat exchanger thermistor abnormality
J6Liquid pipe thermistor abnormality
J8Gas pipe thermistor abnormality
J9Abnormal temperature in electrical box
L3Temperature rise in radiation fin
L4Output overcurrent
L5Radiation fin thermistor abnormality
P4Fan motor system abnormality / fan lock
P9Heater wire abnormality
PAHumidification fan outlet thermistor abnormality / abnormal heater temperature
PHInsufficient gas
U0Over voltage protection (OVP) / low voltage protection (LVP)
U2Signal transmission error (indoor unit – outdoor unit)
Outdoor unit PCB abnormality or communication circuit abnormality
U4Signal transmission error on outdoor unit PCB
U7Incompatible power supply between indoor unit and outdoor unit
UAIncomplete setting for hose length

 

Daikin Mcquay Thermostat Error Codes

Fault codeDescriptionCause for the fault
AUAuto DamperControl setup indicator damper is in “automatic” mode.
AuAuto HP/EControl setup indicator heat pump electric is in automatic changeover mode (HP/E).
boBrown Out or Low VoltageBrown Out – Control monitors input voltage to prevent relay chattering. When voltage drops below 17 VAC, outputs are disabled until voltage input increases to 20 VAC or greater.
bYHP/E BypassControl setup indicator, electric heat is bypassed when OCS > 40°.
CELUI CommunicationCommunication Error, connection between LUI and control board.
CLDamper ClosedControl setup indicator damper is in “closed” mode.
CFCoil Freeze ProtectionIndoor coil is < 32° for at least 5 minutes. Compressor and outdoor fan stop and indoor fan continues to run for active defrost. Protection feature and the displayed code are dismissed when indoor coil temperature rised above 49°F.
HiTemperature LimitingHi Room Room Temperature Display Indication ONLY – Indoor air temperature is 5° above Maximum set point. Displayed code is dismissed when IAS temperature is < 5° from Max set point as adjusted in the Set Up Mode.
LALow Ambient LockoutUnit is in cooling mode and outdoor air < 25°. Compressor will cut out.
mSlave Unit Set to be Controlled by a Master UnitWhen slave unit jumper for Control Select is positioned over SEC, slave unit is set to be controlled by a Master control unit.
LCControl Lockout – Lockout ModeDisplays for 5 seconds when any button is pushed when in the “lockout mode”. To initiate, hold MODE button for 10 seconds.
LoTemperature LimitingLow Room Room Temperature Display Indication ONLY – Indoor air temperature is < 5° below minimum set point. Displayed code is dismissed when IAS temperature is > 5° from Minimum set point as adjusted In the Set Up Mode.
nLControl Lockout – Normal ControlDisplays for 5 seconds to confirm normal mode of operation when control lock out turned ofT. Initiate by holding MODE button for 10 sec.
rFRoom Freeze ProtectionRoom temperature <41°. Damper closes (Premium board) and unit goes into heat mode.
ShJumper StatusMissing Shunt or not properly installed.
ElIndoor Air SensorIndoor Air Thermister Failure. Sensor missing or Short.
E2Indoor Coil SensorIndoor Coil Thermister Failure. Sensor missing or Short.
E3Outdoor Coil SensorOutdoor Coil Thermister Failure. Sensor missing or Short.
E4Outdoor Air SensorOutdoor Air Thermister Failure. Sensor missing or Short.
E5Heat Fan Lock Out SensorHeat Fan Lock Out Sensor Failure, missing, short on control board or heating medium >250°F. Check for installation/connection of HFLO sensor. Should be on coil return line.

 

Daikin FTXN09KEVJU Thermostat Error Codes

Error CodesDescription
System0Normal
uoRefrigerant shortage
U2Low-voltage detection or over-voltage detection
U4Signal transmission error (between indoor unit and outdoor unit)
UAUnspecified voltage (between indoor unit and outdoor unit)
IndoorA1Indoor unit PCB abnormality
UnitA5Freeze-up protection control or heating peak-cut control
A6Fan motor (DC motor) or related abnormality
C4Indoor heat exchanger thermistor or related abnormality
C9Room temperature thermistor or related abnormality
OutdoorE1Outdoor unit PCB abnormality
UnitE5OL activation (compressor overload)
E6Compressor lock
E7DC fan lock
ESInput overcurrent detection
EAFour-way valve abnormality
F3Discharge pipe temperature control
F6High pressure control in cooling
HOCompressor system sensor abnormality
H6Position sensor abnormality
HSDC voltage / current sensor abnormality (09/12 class only)
H9Outdoor temperature thermistor or related abnormality
J3Discharge pipe thermistor or related abnormality
J6Outdoor heat exchanger thermistor or related abnormality
L3Electrical box temperature rise
L4Radiation fin temperature rise
L5Output overcurrent detection
P4Radiation fin thermistor or related abnormality

 

Daikin Altherma Thermostat Error Codes

SymptomPossible CauseAction
Cool ON or Heat ON is displayed, but no warm or cool air is coming from the registers.1. The heating equipment turns on the fan when the furnace has warmed up to a setpoint.1. Wait one minute after seeing the ON icon and then check the registers.
2. Heating or cooling equipment is not operating.2. Check Heating and Cooling system.
“Service“ Flashing on and off.Control EEPROM write error.Press any key and Check / Re-enter Setup Choices.
“Service” solid on and in temperature display.Indoor temperature sensor open or shortedReplace Control
Display will not come on.1. Blown fuse or tripped circuit breaker.1. Replace fuse or reset breaker.
2. Furnace power switch OFF.2. Turn switch to ON.
3. Furnace blower compartment door or panel loose or not properly installed.3. Replace door panel in proper position to engage safety interlock or door switch.
Temperature display is incorrect.Temperature display needs calibration.Calibrate Sensor.
Cannot set Heating setpoint above 80 degreesDeadband between Heating and Cooling set to highDecrease Deadband setting .
Temperature setting will not change. (Example: Cannot set heating higher or cooling lower).1. Upper and/or lower temperature limits were reached.1. Check the temperature setpoints:
Heating limits are 40 – 85F.
Cooling limits are 65 – 90F.
2. “Keypad locked” is displayed on LCD.2. Unlock keypad – press Up+Down arrow together until icon disappears.